Electronic Ballast for Fluorescent Lamps REGULAR
REGULAR-TF118 |
γͺιδ΄ι‘ΡΊΛΕΝ΄ 18 ΗΡ΅΅μ (1 ΛΕΝ΄) |
|
REGULAR-TF132 |
γͺιδ΄ι‘ΡΊΛΕΝ΄
32 ΗΡ΅΅μ (1 ΛΕΝ΄) |
|
REGULAR-TF136 |
γͺιδ΄ι‘ΡΊΛΕΝ΄
36 ΗΡ΅΅μ (1 ΛΕΝ΄) |
|
Specification |
TF118 |
TF132 |
TF136 |
|
Lamp |
1 x 18 W |
1 x 32 W |
1 x 36 W |
|
Rated voltage |
220 Volt |
220 Volt |
220 Volt |
|
Input current |
0.136 A |
0.242 A |
0.273 A |
|
Input power |
18 W |
32 W |
36 W |
|
Power factor |
>0.6 |
>0.6 |
>0.6 |
Total harmonics
distortion(% THDi) |
≤15% |
≤15% |
≤15% |
|
EMC conform |
CISPR 15 |
CISPR 15 |
CISPR 15 |
|
Ballast lumen factor |
>95% |
>95% |
>95% |
|
Transient protect |
IEC 60929 |
IEC 60929 |
IEC 60929 |
|
Lamp flicker |
Non-Visible |
Non-Visible |
Non-Visible |
Crest factor of lamp
Current |
≤1.7 |
≤1.7 |
≤1.7 |
Can be user with dimmer
for fluorescent lamps |
Yes |
Yes |
Yes |
|
|
 |
 |
 |
|
|
 |
|
|