Electronic Ballast for Fluorescent Lamps
MAXIMA
MAXIMA-TF118E |
γͺιδ΄ι‘ΡΊΛΕΝ΄ 18 ΗΡ΅΅μ (1 ΛΕΝ΄) |
|
MAXIMA-TF132E |
γͺιδ΄ι‘ΡΊΛΕΝ΄
32 ΗΡ΅΅μ (1 ΛΕΝ΄) |
|
MAXIMA-TF136E |
γͺιδ΄ι‘ΡΊΛΕΝ΄
36 ΗΡ΅΅μ (1 ΛΕΝ΄) |
|
MAXIMA-TF218E |
γͺιδ΄ι‘ΡΊΛΕΝ΄
18 ΗΡ΅΅μ (2 ΛΕΝ΄) |
MAXIMA-TF236E |
γͺιδ΄ι‘ΡΊΛΕΝ΄
36 ΗΡ΅΅μ (2 ΛΕΝ΄) |
Specification |
TF118E |
TF132E |
TF136E |
TF218E |
TF236E |
|
Lamp |
1 x 18 W
|
1 x 32 W
|
1 x 36 W
|
2 x 18 W
|
2 x 36 W
|
|
Rated voltage
|
220 Volt
|
220 Volt
|
220 Volt |
220 Volt |
220 Volt
|
|
Input
current |
0.084
A |
0.148
A |
0.167 A |
0.167 A |
0.334
A |
|
Input
power
|
18 W |
32 W |
36 W |
36 W |
72 W |
|
Power
factor |
0.98 |
0.98 |
0.98 |
0.98 |
0.98 |
Total
harmonice|
distortion (% THDi) |
≤10% |
≤10% |
≤10% |
≤10% |
≤10% |
|
EMC conform |
CISPR
15 |
CISPR
15 |
CISPR
15 |
CISPR
15 |
CISPR
15 |
|
Ballast lumen factor
|
>95% |
>95% |
>95% |
>95% |
>95% |
Transient protect
According to lamp
failed protect |
IEC
60929 |
IEC
60929 |
IEC 60929 |
IEC 60929 |
IEC
60929 |
|
Lamp flicker |
Non-Visible |
Non-Visible |
Non-Visible |
Non-Visible |
Non-Visible |
|
Crest factor of lamp Current |
≤1.7 |
≤1.7 |
≤1.7 |
≤1.7 |
≤1.7 |
|
Can be used with dimmer for fluorescent lamps |
Yes |
Yes |
Yes |
Yes |
Yes |
|
|
 |
|
 |
|
|
 |
|
|